Romania – Overhaul and refurbishment work – Execuția lucrărilor la obiectivul de investiții ”Creșterea eficienței energetice a blocurilor de locuințe A1 și G2, Strada Măgura, Geoagiu-Băi, Oraș Geoagiu, județul Hunedoara, COD SMIS 2021: 348245
Description
**Residential Building A1 and G2**
**Thermal rehabilitation of the building envelope elements;**
**i. Thermal insulation of the façade - glazed part, respectively the replacement of the existing exterior joinery, including that of the access to the building, with high-performance thermally insulated joinery, replacement of the interior joinery: access doors and windows to unheated or insufficiently heated spaces if the case;**
**ii. Thermal insulation of the façade - opaque part, respectively the thermal insulation of the exterior walls, including the thermo-hydro insulation of the terrace or the thermal insulation of the slab above the top floor with thermo-insulating systems in case of the existence of the roof; Thermal insulation of the opaque exterior walls – by applying to the exterior a thermo-insulating material – mineral wool with a thickness of 20 cm;**
**iii. Closing of the balconies and/or loggias with thermally insulated joinery, including the thermal insulation of their parapets; Demolition of the metal grilles, balustrades and closures not corresponding to the balcony and loggia parapets, as well as the demolition of non-structural, decorative elements made of concrete; Closing of the parapet on balconies and loggias with masonry of 10 cm thickness, plastered and finished with washable plaster and gravel on the interior; Installation of new exterior joinery from PVC with thermally insulated glass of the triplex type, energy efficient, with thermal performance (treated low-E surface, inert gas filling between glass panes, radiant barrier) with R’min = 0.83 m2K/W, including the provision of the glazed façade with shading elements.**
**iv. Thermal insulation of the slab above the unheated basement; Thermal insulation of the slab above the unheated basement - it is recommended to use rigid thermal insulation boards of the type basalt mineral wool of high density, as a thermal insulation material with a thickness of 10 cm, which will be protected with 2 layers of plaster and a reinforcing mesh.**
**v. Thermal insulation of the walls that form the building envelope which delimit the heated space from other unheated common spaces; Insulation of the partitions and partitions with high-density basalt mineral wool with a thickness of 2 cm + protection with reinforced plaster mesh; Insulation of the building's plinth with mineral wool with a thickness of 20 cm and protection with a structured, waterproof but vapour-permeable mortar, with the extension of the thermal insulation with 40 cm below the CTS level;**
**vi. Other types of works: - repair of the protective sidewalk, in order to eliminate the infiltration of the infrastructure of the residential building; - hydro-insulation of the plinth and rehabilitation of the green area around the residential building, affected by the intervention works; - dismantling of the roofing and the wooden roof, dismantling and rebuilding the hydro-insulation layer at the accessible roofs, making the wooden roof and ceramic profiled roofing, including accessories, replacement of the rainwater collection system; - repair of the building façade construction elements that present a potential risk of detachment and/or affect the functionality of the building; - refurbishment of the interior finishes in the intervention areas;**
**Improvement/modernization of the building's technical systems: Providing apartments with ventilation grilles. i. Refurbishment of the ventilation ducts from apartments in order to maintain/achieve the natural ventilation of the occupied spaces, in case these have been blocked/closed; ii. Other types of works: Realization of a new electrical installation (for common areas) and the total use of LED type lighting bodies at the level of the common areas and the exterior lighting areas, having cells with a natural light sensor, powered by electrical energy from SEN; Realization of a lightning protection system and voltage arresters on the electrical power supply. Installation of a system for generating electrical energy with renewable systems of the type "on-grid" photovoltaic panels of 3 kWp/per each block.**
CPV codes
Documents & submission
Contains data from Tenders Electronic Daily (TED), © European Union, ted.europa.eu — CC BY 4.0.
Related tenders
Romania – Multi-purpose sports facilities construction work – Execuție lucrări pentru obiectivul „Construire Sala Polivalentă în Municipiul Iași”
Municipiul IasiRomaniaMulti-purpose sports facilities construction workDeadline in 23 daysPublished on Oct 11, 2026
Romania – Construction work for tunnels, shafts and subways – Servicii de proiectare și execuție a lucrărilor pentru REALIZARE PASAJ RUTIER DJ 172 INTERSECȚIE CU LINIA CFR ȘI DN17 ÎN LOCALITATEA BECLEAN, JUDEȚUL BISTRIȚA NĂSĂUD
ORASUL BECLEANRomaniaConstruction work for tunnels, shafts and subwaysRoad markingsRoad construction worksDeadline in 10 daysPublished on Oct 11, 2026
Romania – Thermal insulation work – Eficientizare termica cladiri rezidentiale, Etapa XVII-BL17, Str. 8 Martie, orasul Petrila, COD SMIS 354795
ORASUL PETRILARomaniaThermal insulation workDeadline in 10 daysPublished on Oct 11, 2026
Romania – Construction work – Executia lucrarilor pentru obiectivul de investitii “Imbunatatirea infrastructurii educationale la Liceul Teoretic Ion Constantin Bratianu Hateg prin constructia unui corp nou de cladire pentru invatamantul liceal –filiera tehnologica”, cod SMIS 364301
ORASUL HATEGRomaniaConstruction workConstruction work for buildings relating to education and researchBuilding installation workDeadline in 7 daysPublished on Oct 11, 2026