Skip to content
Back to search
This tender has been withdrawn.

Germany – Medical equipments – 2 (zwei) Linearbeschleuniger Gesamtsysteme für die Strahlentherapie

Universitätsklinikum Halle (Saale) AöRGermanyPublished on Oct 01, 2026
Deadline passed

Description

Two universally deployable C-arm linear accelerator systems, including a Record&Verify System (R&V) for radiotherapy, are offered. Both offered linear accelerators must be suitable for a wide range of radiation treatments and irradiation techniques with very high precision. Both systems must be suitable, among other things, for 2D and 3D IGRT, IMRT, VMAT, SBRT, SRS and adaptive radiotherapy (ART). Both linear accelerators require an SGRT system and also a CBCT imaging with the best possible image quality and the greatest possible accuracy (HU) with the fastest possible image acquisition. The two offered linear accelerators must be able to be operated as a tandem and must be matched to each other. Consequently, two identical MLCs are required, which must be suitable for high-resolution beam shaping for SRS. Both linear accelerators should also include a treatment table (6-D) that enables a positioning correction in six degrees of freedom (three translations (X, Y, Z) and three rotations about the respective axes). A complete overall system consisting of two linear accelerator systems including all necessary additional systems and including the necessary accessories as well as a Record and Verify System (R&V) is to be offered. In addition, all associated services, the dismantling and disposal of the old systems, an associated full-service contract and the provision of the required device-specific construction and installation services are to be offered. This procurement is a replacement procurement. The new linear accelerators must be commissioned one after the other so that radiotherapy can always ensure patient care. The Record&Verify System (R&V) must be operational and fully functional upon commissioning of the first new linear accelerator. Both linear accelerators must be matched so that they can be used with a single set of basic data in our existing radiation treatment planning system (Raystation). This should avoid any replanning/recalculation between the two offered linear accelerators, so that patients can switch between the devices without any problems.

CPV codes

Medical equipmentsRadiotherapy, mechanotherapy, electrotherapy and physical therapy devicesLinear accelerators

Documents & submission

AI summary
Sign in for an AI summary

Contains data from Tenders Electronic Daily (TED), © European Union, ted.europa.eu — CC BY 4.0.

Related tenders